Scanning Systems SR-360, SR-380 Scanner
Note: The SR-360 may be configured for hardware or software flow control. The SR-380 will only use hardware
flow control.
Scanning Systems to DCB mux cable - Thanks to Walt Schafer, Alton School District
Signal | SR-360
DB25P | Direction | SR
RJ45 | SPL
DB25P | Signal |
RxD | 2 | <=== | 5 | 3 | RxD |
TxD | 3 | ===> | 6 | 2 | TxD |
CTS | 4 | <=== | 7 | 5 | CTS |
RTS | 5 | ===> | 3 | 11 | Busy |
DTR | 6 | ===> | 8 | 4 | RTS |
SGND | 7 | ==== | 4 | 7 | SGND |
DSR | 20 | <=== | 2 | 8 | DCD |