Scanning Systems SR-360, SR-380 Scanner

Note: The SR-360 may be configured for hardware or software flow control. The SR-380 will only use hardware flow control.

Scanning Systems to DCB mux cable - Thanks to Walt Schafer, Alton School District

SignalSR-360 DB25PDirectionSR RJ45SPL DB25PSignal
RxD2<===53RxD
TxD3===>62TxD
CTS4<===75CTS
RTS5===>311Busy
DTR6===>84RTS
SGND7====47SGND
DSR20<===28DCD