Microcom 410 printer
Note: This printer defaults to 9600 baud, 8 data bits, no parity, 1 stop bit with both hardware and software flow
control. The configuration may be changed through software commands. If Xon/Xoff flow control is used, the only
signals required are RxD, TxD, and GND. If hardware flow control is used, a CTS signal is provided and an RTS
signal is required. Xon/Xoff may be disabled through software commands. This printer also has a parallel port on a
DB25 connector.
Microcom to DCB mux cable - Thanks to Raymond Lee, The Guitar Center
Signal | Microcom
DE9P | Direction | SR RJ45 | SPL
DB25P | Signal |
DCD | 1 | ===> | 2 | 8 | DCD |
TxD | 2 | ===> | 5 | 3 | RxD |
RxD | 3 | <=== | 6 | 2 | TxD |
DTR | 4 | ===> | 8 | 4 | RTS |
GND | 5 | ==== | 4 | 7 | SGND |
DSR | 6 | ===> | 1 | 6 | DSR |
RTS | 7 | <=== | 3 | 11 | Busy |
CTS | 8 | ===> | 7 | 5 | CTS |