Alpha Microsystems AM-314, AM318, AM-359

Note: Hardware flow control must be used when printers are to be slaved to terminals. Control codes sent to terminals with slaved printers may contain embedded flow control characters which will stop flow of data. Alpha Micro host must be set for hardware flow control. Mux ports at host must be set for CNB (CTS No Busy). Mux ports at remote must be set for CBL (CTS Busy Low). Terminals and printers must be set for DTR flow control.

Alpha Micro AM-314 to DCB mux cable

Alpha Micro DE9PDirectionSR RJ45SPL DB25PSignal
2<===53RxD
3===>62TxD
4<===75CTS
5====>311Busy
7====47SGND
Available from DCB as Alpha Micro Adaptor and Line Cord

 

Alpha Micro AM-318 / 359 to DCB mux cable

Alpha Micro RJ45DirectionSR RJ45SPL DB25PSignal
1<===N/C (1)6CTS
2<===75CTS
3===>62TxD
4===>311Busy
5<===53RxD
6<===84CTS
7====47SGND
Available from DCB as CPU-9 cable.
This is a NON-SYMMETRICAL cable. Label must be on the Alpha Micro end. Color - Blue

Alpha Micro AM-318 to DCB mux cable

Alpha Micro RJ11DirectionSR RJ45SPL DB25PSignal
1<===75CTS
2===>62TxD
3===>311Busy
4<===53RxD
6====47SGND